FREE SHIPPING
Free shipping on all US order or order above $200
Meanwell RSP-1600-24 is a 1600W single output enclosed type AC/DC power supply with 24V67A0-67A1608W200 mVp-p23.5-30V. It is designed 1U low profile, PFC function and high-power density up to 25W/inch³. As the efficiency reaches high up to 93% with Universal AC input/Full range, RSP-1600-24 works for 90~264VACinput voltage and equipped with the DC output mostly demanded from the industry. The model is cooled by the thermostatically controlled fan, and could operate under the temperature up to 70℃. Additionally, RSP-1600-24 supplies the vast design flexibility by various built-in functions such as the output programming, active current sharing, remote ON-OF F control, auxiliary power, etc. Apart from them, the unit provides the complete protections such as Short circuit, Overload, Over voltage, Over temperature and Optional PMBus or CANBus protocol. Thanks to its longevity, high reliability and excellent quality, Meanwell RSP-1600-24 functions as a high-performance power supply solution for various industrial applications such as industrial control systems, IC test equipment, instrumentation, telecommunications, data storage, laser engraving machines, charging systems and so on.
RSP | Series Name |
1600 | Output Wattage |
24 | Output Voltage (12V/24V/27V/36V/48V) |
**** | Communications Protocol |
Blank | None |
PM | PMBus Protocol By Request |
CAN | CANBus Protocol By Request |
Model | RSP-1600-24 | |
Output | DC VOLTAGE | 24V |
RATED CURRENT | 67A | |
CURRENT RANGE | 0-67A | |
RATED POWER | 1608W | |
RIPPLE & NOISE (max.) | 200 mVp-p | |
VOLTAGE ADJ. RANGE | 23.5-30V | |
VOLTAGE TOLERANCE | ±1% | |
LINE REGUL ATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE TIME | 1500ms, 60ms/230VAC at full load | |
HOLD UP TIME | 16ms / 230VAC at 75% load 10ms / 230VAC at full load | |
Input | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | 0.97/230VAC at full load | |
EFFICIENCY (Typ.) | 91.50% | |
AC CURRENT (Typ.) | 15A/115VAC 8.5A/230VAC | |
INRUSH CURRENT (Typ. ) | COLD START 35A/230VAC | |
LEAKAGE CURR ENT | <2mA / 230VAC | |
PROTECTION | OVERLOAD | 105 ~ 115% rated output power |
Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover | ||
OVER VOLTAGE | 31.5-37.5V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | |
FUNCTION | OUTPUT VOLTAGE PROGRAMMABLE(PV) | Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V). |
OUTPUT CURRENT PROGRAMMABLE(PC) | Adjustment of constant current level is allowable to 20 ~ 100% of rated current | |
AUXILIARY POWER | 5V @ 0.3A, 12V @ 0.8A | |
REMOTE ON-OFF CONTROL | By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual | |
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual | |
ALARM SIGNAL | Isolated signal output for T-alarm and DC OK | |
ENVIRONMENT | WORKING TEMP | -30 ~ +70℃(Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY &EMC | SAFETY STANDARDS | UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |
EMC IMMUNITY | BS EN/EN55024, BS EN/EN61000-6-2, BSMI CNS13438 | |
Others | MTBF | 478.8K hrs min. Telcordia SR-332 (Bellcore) ; 42.1K hrs min. MIL-HDBK-217F (25℃) |
DIMENSION | 300*85*41mm (L*W*H) | |
PACKING | 2.1Kg;6pcs/13.6Kg/1.25CUFT |
l 5 years warranty
l Built-in active PFC function
l High efficiency up to 93%
l Forced air cooling by built-in DC fan
l Optional PMBus or CANBus protocol
l Output voltage and constant current level programmable
l Active current sharing up to 9600W (5+1)
l Protections: Short circuit/Overload/Over voltage/Over temperature
l Universal AC input/Full range (Withstand 300V AC surge input for 5 seconds)
l Built-in remote ON-OFF control/remote sense/auxiliary power/DC OK signal/OTP alarm signal
l Aging facility
l Digital broadcasting
l Constant current source
l Redundant system
l Factory control or automation apparatus
l Test and measurement instrument
l Laser related machine
Brand | Meanwell |
---|
Abundant supply to meet market demand. The warehouse is rich in goods with all kinds of commodities, which Can meet the needs of different customers.
Fast delivery and high efficiency. The warehouse has sufficient supply, when customers need to order, we can quickly find the goods, and deliver out, which effectively improves the efficiency and saves valuable time for customers
Our products have more advantages in price. We always believe that you should enjoy higher quality with lower price. Therefore, we are committed to providing consumers with the most cost-effective products.
No matter how great our goals are, or how many great things waiting for us to do, we must keep our promises and do it well. Because these is one word that cannot be missing in the secret of success. That is "integrity".
Free shipping on all US order or order above $200
Contact us 24 hours a day, 7 days a week
Simply return it within 30 days for an exchange.
We ensure secure payment with PEV