Meanwell HLN-60H-42 is 60W Single Output Switching Power Supply with 42V25.2-42V1.45A60.9W300mVp-p40-46V. The model stands out with dual-stage power factor correction, constant voltage and constant current mode. The constant current value and constant voltage value can be adjusted for Type A, and the type B version is dimming LED power supply, which can be dimmed in three modes. In addition, the built-in two-stage active PFC function meets the requirements of EN61000-3-2 Class C (under 60% load) of the EU harmonic interference limit, and PF> 0.9 limit above 60% load. HLN-60H-42 is able to withstand industrial-grade instantaneous lightning surge 4KV (EN61000-4-5). The efficiency reaches high up to 90.5%, so it can only use natural air cooling heat dissipation to operate at -40°C ~+50°C. Apart from them, HLN-60H-42 is supplied with various protection such as short circuit, overload, over voltage, and over temperature. The item is also certified with UL/CUL/TUV/CB/CE and other international certifications including UL8750, EN61347-2-13. Because of its longevity, high efficiency, and excellent reliability, Meanwell HLN-60H-42 is suitable for LED indoor lighting and LED electronic billboard related applications.
Model | HLN-60H-42□ | |
OUTPUT | DC VOLTAGE | 42V |
CONSTANT CURRENT REGION | 25.2-42V | |
RATED CURRENT | 1.45A | |
RATED POWER | 60.9W | |
RIPPLE & NOISE (max.) | 300mVp-p | |
VOLTAGE ADJ. RANGE | 40-46V | |
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer A type only | |
0.97-0.45A | ||
VOLTAGE TOLERANCE | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP TIME | 500ms, 80ms at full load 230VAC / 115VAC | |
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | |
TOTAL HARMONIC DISTORTION | THD< 20% when output loading>=60% at 115VAC/230VAC input and output loading>=75% at 277VAC input | |
EFFICIENCY (Typ.) | 90.00% | |
AC CURRENT (Typ.) | 0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC | |
INRUSH CURRENT(Typ.) | COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA / 277VAC | |
PROTECTION | OVER CURRENT | 95 ~ 108% |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |
OVER VOLTAGE | 48-58V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |
ENVIRONMENT | WORKING TEMP | -40 ~ +50℃ (Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 40℃) | |
VIBRATION | 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | UL8750, CSA C22.2 No. 250.0-08, BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, IP64, EAC TP TC 004,GB19510.1,GB19510.14 approved ; design refer to UL60950-1, BS EN/EN60335-1 |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |
EMC EMISSION | Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (>=60% load) ; BS EN/EN61000-3-3, GB17743 and GB17625.1, EAC TP TC 020 | |
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), EAC TP TC 020 | |
Others | MTBF | 3400.0K hrs min. Telcordia SR-332(Bellcore) ; 347.4K hrs min. MIL-HDBK-217F (25℃) |
DIMENSION | 161*61.5*35mm (L*W*H) | |
PACKING | 0.46Kg;32pcs/15.7Kg/1.10CUFT | |
HLN-60H-15A A : IP64 rated. Output voltage and constant current level can be adjusted through internal potentiometer. B : lP64 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance. |
l 3 years warranty
l Class 2 power unit
l Built-in active PFC function
l Cooling by free air convection
l Fully isolated plastic case with IP64 level
l Universal AC input/ Full range (up to 305VAC)
l Compliance to worldwide safety regulations for lighting
l Suitable for dry 1 damp locations or outdoor application
l Three in one dimming function (1~10Vdc or PWM signal or resistance)
l Suitable for LED lighting, Industrial Lighting and moving sign applications
l OCP point adjustable through output cable or internal potentiometer
l Protections: Short circuit/Over current/Over voltage/Over temperature
Brand | Meanwell |
---|
Abundant supply to meet market demand. The warehouse is rich in goods with all kinds of commodities, which Can meet the needs of different customers.
Fast delivery and high efficiency. The warehouse has sufficient supply, when customers need to order, we can quickly find the goods, and deliver out, which effectively improves the efficiency and saves valuable time for customers
Our products have more advantages in price. We always believe that you should enjoy higher quality with lower price. Therefore, we are committed to providing consumers with the most cost-effective products.
No matter how great our goals are, or how many great things waiting for us to do, we must keep our promises and do it well. Because these is one word that cannot be missing in the secret of success. That is "integrity".
Free shipping on all US order or order above $200
Contact us 24 hours a day, 7 days a week
Simply return it within 30 days for an exchange.
We ensure secure payment with PEV