FREE SHIPPING
Free shipping on all US order or order above $200
Meanwell DDR-240C-48 is a 240W DIN Rail type DC-DC converter with 48V5A0-5A240W7.5A360W (3sec)100mVp-p48-56V. The unit stands out with ultra-thin rail type chassis design. The main features include easy installation of hanging rails, a face width of only 40mm, which greatly reduces the lack of space on the system end rail (TS-35/7.5 or 15), 2:1 wide voltage input, 4000VDC input/output isolation (with reinforced insulation), -40~+70°C operating temperature, and 150% peak load capacity. In addition, DDR-240C-48 can be paralleled to 960W (3+1 units), and withstands 5G resistance... etc. The design passes IEC62368-1/EN55032, EAC TP TC004 and railway EN50155 regulations certification, which could be used for industrial & railway control, security control, communication system and other fields.
What’s more, this series of models has input options: 33.6 ~ 67.2Vdc, and two output options: 24V/48V. Suitable applications include to DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.
DDR | Series Name |
240 | Rated Wattage |
C | Input Voltage (B: 16.8-33.6Vdc, C: 33.6-67.2Vdc, D: 67.2-154Vdc) |
48 | Output Voltage (24/48Vdc) |
MODEL | DDR-240C-48 | |
OUTPUT | DC VOLTAGE | 48V |
RATED CURRENT | 5A | |
CURRENT RANGE | 0-5A | |
RATED POWER | 240W | |
PEAK CURRENT | 7.5A | |
PEAK POWER | 360W (3sec) | |
RIPPLE & NOISE (max.) | 100mVp-p | |
VOLTAGE ADJ. RANGE | 48-56V | |
VOLTAGE TOLERANCE | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.0% | |
SETUP, RISE TIME | 500ms, 60ms | |
HOLD UP TIME (Typ.) | Please refer to page 6 Hold up Time( Load de-rating curve ) | |
INPUT | VOLTAGE RANGE CONTINUOUS | 33.6 ~ 67.2Vdc |
VOLTAGE RANGE 100ms | 28.8 ~33.6Vdc | |
EFFICIENCY (Typ.) | 92% | |
DC CURRENT (Typ.) | 5.6A at 48Vdc | |
INRUSH CURRENT (Typ.) | 30A | |
INTERRUPTION OF VOLTAGE SUPPLY | EN50155:2007-B/C- type comply with S2 level (10ms) at 70% load ; D-type comply with S2 level (10ms) at full load | |
EN50155:2017-Comply with S1 level | ||
PROTECTION | OVERLOAD | Normally works within 150% rated output power for more than 3 seconds and then constant current protection 105~135% rated output power with auto-recovery |
OVER VOLTAGE | 57.6 ~ 65.0V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |
UNDER VOLTAGE LOCKOUT | 48Vin (C - type): Power ON>=33.6V, OFF<=33V | |
FUNCTION | DC OK REALY CONTACT RATINGS (max.) | 30Vdc/1A resistive load |
CURRENT SHARING | Up to 960W (3+1 units). Please refer to the Function Manual | |
REMOTE ON-OFF CONTROL | Please refer to the Function Manual | |
ENVIRONMENT | WORKING TEMP. | -40 ~ +70℃ (Refer to "Derating Curve") |
WORKING HUMIDITY | 5~95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85℃, 5~95% RH non-condensing | |
TEMP. COEFFICIENT | ±0.03%/℃(0 ~ 60℃) | |
VIBRATION | Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373 | |
OPERATING ALTITUDE | 5000 meters | |
SAFETY&EMC | SAFETY STANDARDS | IEC 62368-1, UL 62368-1, EAC TP TC 004, AS/NZS 62368.1 approved |
WITHSTAND VOLTAGE | I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:0.71KVdc | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25℃/ 70% RH | |
EMC IMMUNITY | BS EN/EN55035 , BS EN/EN61000-6-2 (BS EN/EN50082-2) | |
RAILWAY STANDARD | Compliance to BS EN/EN45545-2 for fire protection ; Meet BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC | |
OTHERS | MTBF | 1415.6K hrs min. Telcordia SR-332 (Bellcore) ; 189.9K hrs min. MIL-HDBK-217F (25℃) |
DIMENSION | 40*125.2*113.5mm (W*H*D) | |
PACKING | 0.76Kg;20psc/16.2Kg/1.16CUFT |
l Width only 40mm
l 3 years warranty
l DC OK relay contact
l Remote ON-OFF control
l 2:1 wide input range
l -40~+70℃ wide working temperature
l 150% peak load capability
l Current sharing up to 960W (3+1)
l DC output adjustable
l Cooling by free air convection
l Can be installed on DIN rail TS -35/7.5or 15
l 4KVdc I/O isolation (Reinforced isolation)
l Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
l Protections: Short circuit/Overload /Over voltage/Over temperature/Input reverse polarity/Input under voltage protection
l Factory automation
l Electro-mechanical
l Wireless network
l Industrial control system
l Telecom or datacom system
l Bus, tram, metro or railway system
l Semi-conductor fabrication equipment
Brand | Meanwell |
---|
Abundant supply to meet market demand. The warehouse is rich in goods with all kinds of commodities, which Can meet the needs of different customers.
Fast delivery and high efficiency. The warehouse has sufficient supply, when customers need to order, we can quickly find the goods, and deliver out, which effectively improves the efficiency and saves valuable time for customers
Our products have more advantages in price. We always believe that you should enjoy higher quality with lower price. Therefore, we are committed to providing consumers with the most cost-effective products.
No matter how great our goals are, or how many great things waiting for us to do, we must keep our promises and do it well. Because these is one word that cannot be missing in the secret of success. That is "integrity".
Free shipping on all US order or order above $200
Contact us 24 hours a day, 7 days a week
Simply return it within 30 days for an exchange.
We ensure secure payment with PEV